[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
[sdpd] Re: RIET:XRDU:Clay: ConvX powder data interconverter for Windows by Mark Bowden
At the ConvX website it is mentioned that ConxX can't convert to
FullProf format. If one chooses "DBW" for the output style, the
resulting file is very close to the format nr. 2 in the list of data
files in WinPlotr [INSTR=0 in FullProf syntax]. There's just one
additional space between the max 2theta and the title that is
needed on the first line. For example:
---from ConvX---
24.000 0.050 157.900Y3FE2(ALO4)3 RT 1.909
162 178 155 166 180 181 170 170
165 183 192 187 197 202 192 187
176 174 194 196 182 188 199 211
---After editing---
24.000 0.050 157.900 Y3FE2(ALO4)3 RT 1.909
162 178 155 166 180 181 170 170
165 183 192 187 197 202 192 187
176 174 194 196 182 188 199 211
Best Regards to all
-Markus
--- In sdpd...@yahoogroups.com, "L. Cranswick" <l.m.d.cranswick...@d...>
wrote:
> ConvX can .....
> ....and writes :
> Philips VAX - APD Philips PC - APD (RD format) RIET7 Rietveld
> GSAS GSAS
> ASCII 2-theta,I lists SCANPI Sietronics CPI Siemens DiffracPlus.
>
Yahoo! Groups Links
To visit your group on the web, go to:
http://groups.yahoo.com/group/sdpd/
To unsubscribe from this group, send an email to:
sdpd-unsubscribe...@yahoogroups.com
Your use of Yahoo! Groups is subject to:
http://docs.yahoo.com/info/terms/